HomeAccount
Your cart : Ł 0.00
Blog

When to Use Sample Probes

When to Use Sample Probes It has been called the 'horn', the 'megaphone', the 'funnel', and even the 'big sucky thing'. Occasionally it is called a sample probe.
Officially, it is an isokinetic sample probe.

Isokinetic means that in a laminar flow area, the air flows in and around the probe without creating any turbulence.

To understand why this is important, we need to understand a fundamental difference between micro and macro particles. While 5 µm particles may seem infinitely small when we consider that our hair is 70 µm to 100 µm in diameter, 5 µm particles exhibit surprising inertia compared to submicron particles. If one were to sample without a sample probe, 5 µm and larger particles would have to be very close to the inlet before they would be pulled over to the inlet. However, the inlet would be surrounded by turbulence, and the turbulent air would repel particles that were being pulled over to the inlet. So, without an isokinetic sample probe, we lose 5 µm particles that should be counted, whether we are sampling in laminar flow or turbulent flow...
Created On  22 Nov 2017 8:30  -  Permalink
0 Comments Read more... 

CLiMET User Authenticator for CI-x5x Series Particle Counters

CLiMET User Authenticator for CI-x5x Series Particle Counters

The FDA regulation 21 CFR Part 11 defines the requirements for electronic records to be considered reliable in a regulated industry.

The majority of CLiMET users are in regulated industries which include pharmaceutical manufacturers, medical device manufacturers and biotech companies. In order for electronic records to be considered reliable, the company must implement controls to insure that only authorized users can have access to the data and that the data cannot be altered. IT departments in regulated industries utilize strong security policies, such as password aging, strong passwords, prevention of duplicate users, control of file access, and control of program access. Administrators can quickly add and remove users and change permissions. Users can change their password once and it is good for any device on the network that they are authorized to use. If only the particle counters could have the same user authentication policies as the network! Now there is a way...


Created On  21 Nov 2017 15:52  -  Permalink
0 Comments Read more... 

NextGen Series™ Portable Particle Counter

NextGen Series™ Portable Particle Counter

Introducing the smallest and lightest Industrial and Pharmaceutical Grade Particle Counter with stainless steel enclosure, 6 Channels, a built-in printer, PDF Reports, and the most advanced technology - ensuring the highest level of accuracy and repeatability of measurement. Drop and vibration tested for industrial use...

Created On  21 Nov 2017 12:24  -  Permalink
0 Comments Read more... 

Trident Series™ Particle Counter

Trident Series™ Particle Counter Climet Instruments Company, a Division of Venturedyne Ltd, the leading manufacturer of high quality cleanroom particle counters and microbial samplers, recently announced the introduction of a new Trident Series™ of remote sensor particle counters used for continuous monitoring in biopharmaceutical critical clean areas...
Created On  20 Jun 2017 10:53  -  Permalink
0 Comments Read more... 

Climet CI-500 Particle Counters

Climet CI-500 Particle Counters The lens manufacturer has ceased production of the lenses required to replace laser diodes in Climet CI-500 Particle Counters. We have since been informed that the stock of these lenses has now been depleted, and as such, they can no longer be obtained.

We are now unable to replace failing laser diodes in Climet CI-500-A, CI-500-B, CI-500-EC, CI-500-DD and CI-500-EX (Multiport) Particle Counters...

Created On  8 Mar 2017 10:57  -  Permalink
0 Comments Read more... 

NEW! RIGEL Aerosol Photometers & Generators

NEW! RIGEL Aerosol Photometers & Generators It is with great pleasure that OptiCal Sciences Limited proudly presents new RIGEL RI7001 Aerosol Photometers, RI8301 Thermal Aerosol Generators & RI8303 Laskin-Nozzle Aerosol Generators; available to purchase from both the United Kingdom and Ireland companies.
Established in 2008, RIGEL Life Sciences offers highly competitive solutions, whilst meeting and surpassing requirements of client engineering and GMP compliance teams within the Life Science Industries...
Created On  21 Sep 2016 17:03  -  Permalink
0 Comments Read more... 
 

ISO 9001:2008 Certification

We are currently certificated to the requirements of ISO 9001:2008 by Intertek Group PLC, who are accredited by the United Kingdom Accreditation Service (UKAS). UKAS, as an accreditation body, work with other similar bodies around the world to ensure that the standard of auditing is uniform and adequate. Some certification bodies do not have this accreditation and therefore the standard of their auditing has not been independently verified. For further details please see the web page linked here: http://www.ukas.com/about-accreditation/default.asp

Please click here to view a copy of our ISO 9001:2008 Certificate